Hi all i have a random problem with a ctec 800 nurse call system. Ideal for any nursecall, dementia, staff protection, emergency assistance or affray. The 4000 series visual nurse call system, the independant wireless nurse call system, and the inform mobile nurse call system are all excellent nurse call systems for hospitals. Intercall 600 the best selling nonspeech nurse call. For example, messages can now be sent to different.
Radiation oncologytoxicityquantec wikibooks, open books. Great flexibility, coupled with many other advanced features such as multiple call levels, free builtin datalogging, simple system reprogramming and full monitoring of all network devices, makes ctec. Please see our quick guide to compatibility for some of the uks most popular systems. Quantec addressable call system quantec is a powerful yet easy to use call system. Because it uses ip technology, all communications can use the same physical environment. Stainless steel glazed enclosure for quantec controller. Ctec quantec addressable infrared call point, button reset c. The newest member of the intercall family, the touch series is a modern nurse call system offering easy communication and management of patient care. Nurse call systems for assisted living facilities cornell. Designed to be positioned at the bedside, the call point generates a call by a button or a call lead. The way the system operates can be tailored to suit a care facilitys specific requirements with different day, night and call divert arrangements easily accommodated to meet the exact operational needs and precise layout of any building. The unit plays a melody and a confirmation message is displayed. Quantec master infrared ceiling receiver irish safety systems. Nurse call direct ctec qt6012 quantec control panel.
Capable of monitoring 48 individual zones from a single wall mounted annunciator panel, the 4000 series nurse call system is an ideal choice for hospitals of all sizes. The cms ip software nterfaces directly with the tcpip lan local. Quantec call lead nurse call shop uk nursecall shop. However, for your convenience, the main instructions for each of ctecs product ranges typically our control panel manuals can be downloaded. Quantec is a powerful yet easy to use addressable call system that helps ensure vital communication throughout a building. Allows any call on the quantec system to be routed to handheld alphanumeric pagers in a much more sophisticated way than was previously possible. Addressable call systems the safety centre, uk call systems. As well as offering design and installation services for leading nurse call, staff attack, access control, warden call, cctv and surgery call manufacturers we also design and manufacture our own extensive range of bespoke products. In environments where efficiency is paramount, quantec delivers, helping save staff time.
Fitting a nurse call system can often be disruptive, time consuming and expensive. In an environment where efficiency is paramount, quantec delivers, helping save staff time, minimising disturbance and improving the quality of patient. For more information on call systems, call us now on 01200 428 410 or use the livechat facility below. Ctecs powerful yet easytouse quantec addressable call system.
The intercall touch series is a modern nurse call system offering easy communication and management of patient care. Qt608c quantec nurse call corridor display with controls comsec. Connect the other end of the hjm309 cable into the hjr075 alarm system socket marked. Most previous documentation can be downloaded from there. Quantec nurse call sensor mats compatible with your nurse call alert system. Newsflash announces from the quantec forum starting with 249x rev. Hlv301m mattress pad sensor hjr075 control box hjm309 connection cable. Nurse call handset intercall nurse call system connections. If an organization has cre ated or manufactured a cable to connect the device to the nurse call system, the organization then has taken on the. Ctec quantec nurse call ancillaries pro safety systems. Connect nurse call handset to one connector and a hjm309 cable to the other connector 3.
The quantec call lead allows the user to raise an alarm by pressing the red button on top of the call lead. Introducing the micare nurse call and emergency system 1. Communication and call systems nursecall systems ctec. The control panel will then alarm displaying location, calls are reset via a button on the front. Can also be used to program infrared transmitters used on an 800 series call system. Quantec ctec nursecall systems communication and call. A programmable addressable call point cw remote jack socket for use with ctecs quantec addressable call system. Quantec will prioritise your call, show it on all relevant displays and indicate its higher priority with a more urgent alarm tone easily recognisable by. In an environment where efficiency is paramount, quantec delivers, helping save staff time, minimising disturbance and improving the quality of patient care. Quantec nurse call call lead, quantec nurse call display labels, quantec nurse call jack socket nut. Call system ctec 800 series conventional view products call system ctec quantec addressable.
There is an lcd display screen which show the activations on the system, time, date and location. The 2m and 4m pear push leads are compatible with any nurse call system that supports a stereo fitment such as quantec and 800 series, allowing patients to make a call from. In todays healthcare environments, it is usual for staff in. Instructions and manuals are best downloaded from our individual product pages via the menu bar. The sounders are not working, even though when the alarm is raised they receive 14vdc. In addition, it has many advanced features such as multiple call levels and full monitoring of all network devices. Intuitive and easytouse with comprehensive help files. We have a huge range available from leading manufacturers of nurse call systems. Quantec nurse call accessories spares nursecall shop. They offer a wide range of products and bespoke solutions designed specifically to meet the needs of care homes, care groups, hospitals in both the private and public sectors. It is laptop programmable with the software qt707 and includes space for 2 x 7ah back up batteries which enable the system to continue running in the event of a power failure. Bosch nursecall main unit user manual pdf download.
A collection of quantec wired nurse call equipment including spares. Dnu6012001 before carrying out the following steps. Complete with socket for a call lead and connections for a ceiling pull switch. Qt608c quantec nurse call corridor display with controls page of comsec protection systems ltd, who provide a wide range of products and services including fire alarm systems, cctv systems, intercom systems, lighting systems, and much more. Connect a hlv006 y connector into nurse call system 2. How to replace a device on the quantec call system ctec. Aid call has been leading the way in wireless n urse call technology for over 40 years. With up to 7 levels of call, the systems can be tailored to suit the needs of any facility and is an ideal solution for staff protection, dementia and nurse call scenarios. Making quantec the obvious choice for nursing homes and hospitals alike. Qt608c quantec nurse call corridor display with controls page of comsec protection systems ltd, who provide a wide range of products and services including fire alarm systems, cctv systems, intercom. Quantec is a consultancy providing economic and financial data, country intelligence and quantitative analytical software. Quantec nurse call system wired systems gd systems.
Please note that these are addressable units and you need to know how to programme them into the system. The 2m and 4m pear push leads are compatible with any nurse call system that supports a stereo fitment such as quantec and 800 series, allowing patients to make a call from a chair or bed. Addressable call systems ctec fire alarms call systems. The architect will provide a drawing of the typical nurse call device locations. Nurse call system intercall other type does the room have no. As well as offering design and installation services for leading nurse call, staff attack, access control, warden call, cctv and surgery call manufacturers we also design and manufacture our own. Quantec nurse call schematic technical resources eu. Includes a call button, reset button and redgreen confidence light. Allows compatible quantec call points, sounders, infrared transmitters and universal interface devices to be individually programmed to suit the requirements of individual sites. Should you visit a room to find additional assistance is required, simply reach across to the. In environments where efficiency is paramount, quantec delivers, helping save. Specialist services health technical memorandum 0803. Aid call utilise wireless technology because there is no need to install cables to any. The quantec addressable call system is ideal for nursecall, general call and staff attack applications.
Compatible with all quantec and nursecall 800 systems. For example, messages can now be sent to different pagers dependent on the level of call, the area the call came from and whether the call is made during the day or at night to accommodate lower. Aid call utilise wireless technology because there is no need to install cables to any of the call points and the impact is minimal, which is reassuring at a time of increased pressure on resources and environments. Quantec, one of the most innovative call systems on the market. Quantec is a fully featured system and highly configurable. Instructions and manuals are best downloaded from our individual product pages via the menu bar above. Alcad nurse call system becomes the buildings communication management system thanks to its integration capabilities through the rooms control post or communications server. It is common practice within the call industry to use low voltage signal cable. The qt602 call point forms the basis of the quantec system. Easydata the easydata service provides online access to south african. Contact our team for further information or a free consultation on the installation of a quantec nurse call system.
Often a custom cable connection may need to be created that is not approved for use by the nurse call system or the specific device. Nqt6012 quantec addressable nurse call panel fch243 3. Call system ctec 800 series conventional view products call system ctec quantec addressable view products. This means that alarms of these types will be displayed first. Quantec is a powerful yet easy to use call system that helps ensure vital communication throughout a building.
The cmsip software is used in conjunction with the l7700 ip controller and displays real time information from the call system. Elevations of nurse call devices are to be determined by the architect prior to installation. Quantec general purpose wiring instructions application note q001 page 1. Hlv301m mattress pad sensor hlv301s seat pad sensor. Easydata the easydata service provides online access to south african macroeconomic, industry, international trade and regional indicators and analysis. Please make sure you have read the full quantec instruction manual document number. Ctec quantec nurse call ancillaries great flexibility, coupled with many other advanced features such as multiple call levels, free builtin datalogging, simple system reprogramming and full monitoring of all network devices, makes ctec quantec the obvious choice for nursing homes, hospitals, health centres and many other private and public. As the quantec adapter is fitted the qt633 mat will work direct. It is laptop programmable with the software qt707 and includes space for 2 x 7ah back up batteries which enable the system to. The touch series has been designed using engaging soft forms, balancing technology. They offer a wide range of products and bespoke solutions designed specifically to meet the needs of.